Led signal
DETAILS – LED SIGNAL
LogyTel provides six LED signals designed specifically to present the necessary aspects of the railway signalling for railway lines.
Railway signals are designed with High Brightness LED Technology and features that provide important advantages to railway signalling infrastructure as, high brightness, power consumption, life and maintenance.
Exist three modules integrated inside the LED signal; Optical (leds), Power (current compensation resistances) and Control (Performs the switching between the operating modes and activate the current and voltage protection).
The LED signal designed by LogyTel can be adapted to different railway infrastructures. or to other kind of road infrastructures.
The LED signal has been tested and approved by certified laboratory.
MAIN FEATURES
- Lineal consumption.
- Two switching modes (day / night).
- Switching is activated by power supply level.
- Temporal disconnection when power supply fall is detected.
- Permanent disconnection when hardware fall is detected.
- Safety: SIL 4
- Color light signals (red, green, yellow and blue) are defined by wavelength
- Led viewing angle: 15º
- Aluminum casing
- 160mm optical diameter
CERTIFICATION
EN 21308: High voltage Essays
EN 30034: Electromagnetic compatibility (EMC) to radio paging receiver ERMES European Radio Message System)
EN 50125-3: Environmental conditions for equipment. Telecommunications equipment and signage.
EN-60068: Environmental tests.
EN-60068-2-6: Test Cy: Damp heat steady state, accelerated test primarily applicable to components.
EN-60068-2-17: Test Q: Watertightness
EN-60068-2-27: Tests – Test Ea and guidance: Shock.
EN-60068-2-52: Test Kb: Saline fog, cyclic test k (sodium chloride).
EN-60068-2-66: Test methods. Cx Test: Testing continuous moist heat (steam pressurized unsaturated).
EN 50129: Railway applications. Communication, signalling and processing systems. Safety related electronic systems for signalling.
EN 50261
EN 29000-3
EN 50081
EN 50082
MECHANICAL SPECIFICATIONS
MTBF FOCOLED II TO 25ºC OPERATION TEMPERATURE | ||
COLOR | MTBF (hours) | MTBF (years in continuous operation ) |
RED | 127.174,11 hours | 14,52 years |
YELLOW | 127.174,11 hours | 14,52 years |
GREEN | 166.608,96 hours | 19,02 years |
BLUE | 154.622,41 hours | 17,65 years |
WHITE / DIRECTIONAL WHITE | 166.608,96 hours | 19,02 years |